An All-Fiber FLRD System for SO2 Detection Based on Graphene-Coated Microfiber

PHOTONICS(2023)

引用 0|浏览10
暂无评分
摘要
The accurate and effective detection of SF6 decomposition components inside a gas-insulated switchgear (GIS) is crucial for equipment fault diagnosis and condition assessment. The current method for detecting SF6 decomposition components involves gas extraction at the GIS inlet, which only provides limited information on the decomposition component content. Therefore, there is a need to explore more effective ways to obtain internal gas component information within GIS. In this study, we propose a graphene-coated microfiber gas detection method for SO2. We establish a physical simulation model of the microfiber and analyze the sensing mechanism of the microfiber diameter and cladding refractive index changes in its evanescent field. A graphene-coated microfiber gas sensor was prepared using a drop-coating method, and a fiber loop ring-down (FLRD) gas detection system was constructed for the experimental studies on SO2 gas detection. The results demonstrated that the graphene-coated microfiber exhibits an excellent gas-sensitive response to SO2 and achieves trace-level detection at room temperature. The concentration range of 0 to 200 ppm showed good linearity, with a maximum detection error of 4.76% and a sensitivity of 1.24 ns/ppm for SO2. This study introduces an all-fiber method for detecting SF6 decomposition components, offering a new approach for online monitoring of SF6 decomposition components in GIS equipment using built-in fiber-optic sensors.
更多
查看译文
关键词
so2 detection,all-fiber,graphene-coated
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要