Robust power management in the IBM z13

IBM Journal of Research and Development(2015)

引用 32|浏览203
暂无评分
摘要
The power management strategy adopted for the IBM z13™ processor chip (referred to as the CP or Central Processor chip) is guided by three basic principles: (a) controlling the peak power consumption by setting a realistic limit on the so-called thermal design power or thermal design point (TDP) driven by customer workloads and maximum-power stress microbenchmarks; (b) reduction of the voltage margin by using a novel dynamic guard-banding technique; and (c) the creation of a rich new set of fine-grained, time-synchronized sensors that track performance, power, temperature, and power management behavior for a running machine. A prime requirement of the power management architecture is that the efficient control mechanisms be designed in such a manner that the high standards of IBM z Systems™ application performance and reliability be maintained without any compromise. In this paper, we describe the key features constituting the z13 CP robust power management architecture and design that meet the stipulated objectives.
更多
查看译文
关键词
Radiation detectors,Power system management,Monitoring,Voltage control,Power demand